Fire extinguisher maintenance pdf

The following types of fire extinguishers are considered obsolete and shall be removed from service. Inspection, maintenance and recharge service manual pn 05603 carbon dioxide hand portable fire extinguishers model 3203212 12 lb model 3225 lb model 33115 lb model. Portable fire extinguisher types and maintenance grainger. Maintenance and inspection for fire fighting appliances and equipment ref solas ii2 msc. Portable fire extinguishers inspection, maintenance, and recharge. Fire extinguishers should be regularly serviced to ensure they remain in good working order and function correctlly should they be needed. The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Easy access in an emergencybe sure nothing is blocking or limiting your ability to reach it. Inspection is a quick check that a fire extinguisher is available and is in operating condition. Is it clear of obstructions to access or visibility. Any parts needed during maintenance will be charged at the rates listed below. Fire extinguisher maintenance and monitoring is covered under the inspection and is conducted by external professionals or an organizations own safety officers as part of an overall fire safety strategy. Water or steam type fire extinguishers should be discharged, disassembled and inspected annually nfpa 10, 44. Because these units cannot be recharged, the annual maintenance requirements do not require disassembly of the extinguisher.

The recommended pressure levelmany extinguishers have gauges. Conducting annual fire extinguisher maintenance is the best way to make sure that everything will function the way it is designed in the event of an emergency. These guidelines apply to all ships and describe the minimum level of maintenance and inspections for fire protection systems and appliances. It is not intended for use on an outofcontrol fire, such as one which has. Maintenance is to be performed in full compliance with the maintenance requirements of nfpa10.

Guidelines for monthly fire extinguisher inspections. The maintenance requirements depend on the type of portable fire extinguisher. Is the extinguisher located in its designated location. Fire extinguisher inspection template internal maintenance this fire extinguisher inspection form template is used to document two important processes after fire extinguisher maintenance. Maintenance is a thorough check of the extinguisher. Singapore standard 578 or ss 578 for short governs the use and maintenance of portable fire extinguishers. The following are annual fire extinguisher maintenance steps that should be performed on both commercial and residential fire extinguishers. View and download amerex 344 maintenance service manual online. Stored pressure dry chemical hand portable fire extinguishers pro line. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The current edition of this standard is nfpa 102018 standard for portable fire extinguishers, 2018 edition. The section and paragraph numbers listed in parenthesis refer to nfpa 10 standard for portable fire extinguishers, 2010 edition. Sixyear maintenance is required to be recorded on a metallic label, or similar durable weatherproof material, affixed to each extinguisher that is a minimum 2 in. The supplier must provide mcc with loaner extinguishers without charge where any extinguishers are.

The imo has also published guidance in assembly resolution a. Move forward or around the fire area as the fire diminishes. New fire extinguishers fire extinguisher s year of manufacture can be found on the label e. This type of assurance derives from the proper maintenance, inspection, selection, installation, recharging, and testing of portable fire extinguishers, a series of activities that have long. The fire extinguisher is serviced at a facility and the. Ref solas ii2 maintenance and inspection for fire fighting. Learn more about impact fires preventative maintenance program. First alert offers fire extinguishers for your home or business, in several sizes and types, because having a fire extinguisher on hand can be the difference between minimal damage and a huge catastrophe. International fire code ifc standards for inspection. Fire extinguishers are required to undergo a visual inspection once every month to ensure proper working order. Inspection, maintenance, testing, and recharging periods for. Extin use r for extinguisher location guisher serial i.

Before you continue reading this is a very summarised version of the standard that is not word for word and many parts have been omitted out. Fire extinguishers for homes commercial grade fire. The class, quantity, and placement of fire extinguishers. Stored pressure or dry chemical type extinguishers do not require an internal. Inspection, maintenance, testing, and recharging periods. Verificationof service collar maintenance or recharging each extinguisher that has undergone an internal examination or that has been recharged is required to have a. This information should be used as a basis for the ships onboard maintenance plan required by solas regulation ii214. View and download kidde pro line service manual online. A fire extinguisher inspection is conducted monthly to ensure that fire extinguishers are in good working condition. The section and paragraph numbers listed in parenthesis refer to. Labels indicating fire extinguisher use or classification, or both, shall be permitted to be placed on the front of the fire extinguisher.

See our website for complete details of the maintenance. Fire extinguisher weight vs rating the weight of the extinguisher is based on the amount of the extinguishing agent. Stored pressure or dry chemical type extinguishers do not require an internal examination. Read the instructions that come with the fire extinguisher and become familiar with its parts and operation before a fire breaks out. Fredriksen fire equipment offers the following timetable for any inspection, maintenance, recharging, and testing of portable fire extinguishers. The label needs to indicate the month and year the maintenance was performed by means of a perforation similar to that. Inspection, maintenance and recharge service manual pn 05603 carbon dioxide hand portable fire extinguishers model 3203212 12 lb model 3225 lb model 33115 lb model 33010 lb model 33220 lb all fire extinguishers should be installed, inspected and maintained in accordance. Is the fire extinguisher for your car, business or home in working order. The fire extinguisher or hose must be visually inspected monthly and be subjected to an annual maintenance test. Extinguisher maintenance and services fire protection. In addition, fire extinguishers must be maintained annually in accordance with local, state, and national codes and regulations. Buildingfloorarea type number number purchased j f m a m j j a s o n d notes date. The interval of these procedures vary depending on what type of extinguisher is inspected.

A fire alarm system component that alerts by the sense of hearing e. Form 16a portable fire extinguishers inspection, maintenance. It is intended to give maximum assurance that an extinguisher will operate effectively and safely. Are operating instructions on the name plate legible and facing outward. Inspection is a quick check that a fire extinguisher is. First alert offers fire extinguishers for your home or business, in several sizes and types, because having a. Choose a fire extinguisher that carries the label of an independent testing laboratory. You need your fire extinguisher to perform when you need it. Fire extinguishers can help save lives and property. Annual fire extinguisher maintenance checklist jay l harman. Local fire departments or fire equipment distributors often offer handson fire extinguisher trainings. Fire extinguisher maintenance includes recharge, hydrostatic and maintenance tests as required by law.

Fire extinguishers need servicing every year to make sure they are in proper working order. Fire extinguisher maintenance city and state law requires that extinguishers receive maintenance by a licensed technician on an annual basis. Fire extinguisher placement the selection and distribution of portable fire. Fire extinguishers the right way carry extinguisher to fire then open valve. You can usually find them in hallways, laundry rooms, meeting rooms. Halon 1211 818 seconds discharge time range 916 ft. This extinguisher should be inspected at regular intervals monthly or more often if circumstances dictate to insure that it is ready for use. See our website for complete details of the maintenance required in illinois. The supplier must provide mcc with loaner extinguishers without charge where any extinguishers are removed to complete testing from its current location. Class k commercial kitchens have this type of extinguisher available because it is designed for cooking fires. Fire extinguisher locations fire extinguishers are located throughout the workplace and readily accessible in the event of a fire. The fire extinguisher label will clearly state that the extinguisher is nonrefillable or nonrechargeable and is to be removed from service at a maximum interval of 12 years from the date of. Fire extinguisher maintenance in addition, fire extinguishers must be maintained annually in accordance with local, state, and national codes and regulations. Resources fire protection equipment specifications.

Fire extinguisher maintenance and monitoring is covered under the inspection and is. Summary fire extinguisher monthly quick checklist unit is in proper location. The fire extinguisher label will clearly state that the extinguisher is nonrefillable or nonrechargeable and is to be removed from service at a maximum interval of 12 years from the date of manufacture. Stored pressure extinguishers do not require an internal examination. You can usually find them in hallways, laundry rooms, meeting rooms, kitchens, mechanicalelectrical rooms, and near exit doors. It is the responsibility of a business owner or responsible person for. Fire extinguishers should be maintained at regular intervals at least once a year, or when specifically indicated by an inspection. The fire extinguisher is serviced at a facility and the primary use of the facility is to provide this service to the awarding agency, or c. It is intended to give reasonable assurance that the fire extinguisher is fully charged.

In doing this, the employer must record the annual maintenance date on a tag and. Amerex 344 maintenance service manual pdf download. Fumes toxic if inhaled halon is no longer manufactured halon a trash wood. Types and maintenance of fire extinguishers fireline. A fire extinguisher is an active fire protection device used to extinguish or control small fires, often in emergency situations. It includes a thorough examination and any necessary. Dec 07, 2017 this type of assurance derives from the proper maintenance, inspection, selection, installation, recharging, and testing of portable fire extinguishers, a series of activities that have long been aided by the use of nfpa 10. Operating instructions are facing relatively outward for obvious viewing. When its time to use a fire extinguisher, just remember pull aim squeeze sweep pass. Previous 6 year maintenance and hydrostatic test dates can be found on a sticker on the back of the fire extinguisher. Service and repair of fire extinguishers policy 03102009 page 2 of 2.

Tags or labels intended for recording inspections, maintenance, or charging shall be affixed so as not to obstruct the fire extinguisher use, fire extinguisher classification or manufacturers labels. The fire extinguisher is serviced on the awarding agencys jobsite, or b. It is the responsibility of a business owner or responsible person for a building to ensure that extinguishers are serviced in accordance to the bs 53063. Monthly spot checks do not require any special licensing and can be done by anyone with these instructions. Fire extinguishers shall be located so that the maximum travel distances shall not exceed those specified in table 1. This includes fires involving grease, fat, and oil. Threeparts specifications for fire extinguishers, fire extinguisher cabinets, fire blanket cabinets, extinguisher cabinets. Fire extinguisher inspection a safety officers guide. Extinguisher maintenance and services maintenance and services have you recently checked your fire extinguisher. Starting at the recommended distance, sweep the nozzle or hose from side to side until the fire is out. This is a thorough examination of the fire extinguisher s mechanical parts, fire extinguishing agent, and the expellent gas. Larsens manufacturing company warrants to the original purchaser.